Kane 457 Flue Gas & Ambient Air Analyser
Kane 457 Flue Gas & Ambient Air Analyser
- Availability:Out of stock
- Manufacturer:Kane
- Product Number:Kane 457
- Rep. Product Number:Kane457
ALWAYS REFER TO MANUFACTURER'S INSTRUCTIONS
Kane technical number 01707 375550
- Product Overview
- Description
Supplied Accessories
- Kane 457 Ambient Flue Gas Analyser
- Kane Flue Probe
- Batteries
- Kane Charger
- CO2 True Zero Capsule
- Kane Full Instruction Manual
- Manufactures Calibration Certificate
Features
- Rotary switch for ease of use
- Logs & prints reports with optional infra-red printer
- Combustion
- Pressure
- Let-by & Tightness
- Temperature
- CO & CO2 build up
- Logs & prints ambient CO & CO2
- 5 year warranty if serviced annually by Kane
Application
- Installation, commissioning & servicing of domestic oil or gas appliances
- Commercial Catering
- Safety checks
- CO in a room or around an appliance
- Combustion performance checks
- Combustion efficiency checks
- Flue Draught
- CMDDA1
- Indoor Air Quality
Measures
- CO2 direct with an infra-red sensor 0-20%
- CO2 ppm 0-10,000ppm
- CO 0-2,000ppm
- Differential temperature
- High accuracy differential pressure meter +/-80mbar
Calculates
- O2
- CO/CO2 ratio
- Excess air
- Combustion efficiency
Fuel Types
- Natural Gas
- Butane
- Propane
- LPG
- 28 sec oil
- 35 sec oil
- Wood pellets
Specifications
Parameter | Range | Resolution | Accuracy | |
---|---|---|---|---|
Flue Temperature | 0-600°C | 0.1°C | ±2.0°C ±0.3% reading |
|
Inlet Temperature (Internal Sensor) |
0-50°C | 0.1°C | ±1.0°C ±0.3% reading |
|
Inlet Temperature (External Sensor) |
0-600°C | 0.1°C | ±2.0°C ±0.3% reading |
|
Oxygen*2 | 0-21% | 0.1% | ±0.3%*1 | |
Carbon monoxide | 0-20ppm 21-2000ppm nom 4,000ppm max for 15 mins |
1ppm | ±0.3%*1 ±3ppm ±5% reading |
|
Carbon dioxide | 0-20% | 0.1% | ±0.3% reading | |
Efficiency (Net or Gross)*2 | 0-99.9% | 0.1% | ±1.0% reading | |
Effeciency High (C)*2 | 0-119.9% | 0.1% | ±1.0% reading | |
Excess Air*2 | 0-250% | 0.1% | ±0.2% reading | |
CO/CO2 ratio *2 | 0-0.999 | 0.0001 | ±5% reading | |
Nominal range ±160mBar Maximum over range without damage to sensor is ±800mBar |
±0.2mBar ±1 mBar ±160mBar |
Maximum 0.001 mBar <25 mBar |
±0.005 mBar ±0.03 mBar ±3% of reading |
|
Pre-programmed Fuels | Natural gas, Propane, Butanem LPG, Light Oils (28/35 sec), Wood Pellets | |||
Ambient Measurements Carbon Monoxide |
As above | |||
Carbon Dioxide | 0 to 5000ppm 1ppm ±5% reading 5001 to 9999ppm 5ppm ±8%reading |
|||
Storage Capacity | 99 Combustion tests 20 Pressure tests 20 Tightness tests 20 Temperature tests 20 Room CO tests 20 Ambient tests up to 240 times tests (one sequence only) |
|||
Ambient Operating Range | Temperature – 0°C to 40°C Humidity – 10% to 90% RH non-condensing Atmospheric Pressure – 860 to 1060hPa |
|||
Battery Type / Life | 4AA cells >8 hours using Alkaline AA cells |
|||
Chargers (optional) | 220v charger, for NiMH batteries only 12v in vehicle charger, for NiMH batteries only |
|||
Dimensions | Weight – 0.8kg handset with protective cover Handset – 200 x 45 x 90mm Probe – 300mm long including handle. 6mm diameter x 240mm long stainless steel shaft with 3m neoprene hose. Type K thermocouple |
*1 Using dry gases at STP
*2 Calculated
Optional wireless upgrade
- Transfer analyser readings to your PC using a KANE LIVE software.
- Send printout data to your mobile device using the free Kane printer app.
BTM/450
Wireless android module
|
BTM/450LE
Wireless iOS module
|
Kane 457 Flue Gas & Ambient Air Analyser - Kane 457 Gas Flue Analyser
Unique - ambient & flue CO2 in one analyser Ideal for commercial catering & incident investigations
Kane 457 Flue Gas & Ambient Air Analyser measures carbon dioxide (CO2), carbon monoxide (CO), differential temperature and differential pressure. The direct measurement of CO2 is achieved using a Kane designed infra-red sensing system. CO2 is measured at both flue gas concentrations and at ambient concentrations using two separate sensing systems. These sensing systems are automatically compensated for changes in ambient temperature and in atmospheric pressure. Low flow is automatically detected in both combustion and ambient modes. It can be triggered by low battery voltage, a kinked hose, a full water trap, saturated particle filter or a blockage in the hose or probe. Flue CO2 in % is set to zero in fresh air automatically after the initial countdown. For extra accuracy ambient CO2 in ppm is set to a true zero using a Kane 'ZeroCal Capsule'. If “RESET GAS ZERO” is indicated ensure that the unit is in fresh air before pressing the button with an “Enter” symbol. It calculates oxygen (O2), CO/CO2 ratio, losses, combustion efficiency (Nett, Gross or Condensing) & excess air. The Kane457 Combustion Analyser can also measure CO levels in ambient air - useful when a CO Alarm is triggered. It can also perform a Room CO + CO2 Test for up to 30 minutes duration. The Kane 457 Gas analyser has a rubber protective cover with a magnet for “hands–free” operation and is supplied with a flue probe with integral temperature sensor. The large display shows 4 readings at a time and all data can be printed via an optional infrared printer. The printed data can be 'live' data or ‘stored’ data. The memory can store up to:- 99 combustion tests
- 20 pressure tests
- 20 let-by/tightness tests
- 20 temperature tests
- 20 room tests
- 20 ambient tests
- 240 timed tests