Supplied Accessories
  • Kane 457 Ambient Flue Gas Analyser
  • Kane KMIRP-2 Infrared Printer
  • Kane Carry Case
  • Kane Flue Probe
  • Batteries
  • Kane Charger
  • CO2 True Zero Capsule
  • Kane Full Instruction Manual
  • Manufactures Calibration Certificate
Features
  • Rotary switch for ease of use
  • Logs & prints reports with optional infra-red printer
    • Combustion
    • Pressure
    • Let-by & Tightness
    • Temperature
    • CO & CO2 build up
    • Logs & prints ambient CO & CO2
  • 5 year warranty if serviced annually by Kane
Application
  • Installation, commissioning & servicing of domestic oil or gas appliances
  • Commercial Catering
  • Safety checks
  • CO in a room or around an appliance
  • Combustion performance checks
  • Combustion efficiency checks
  • Flue Draught
  • CMDDA1
  • Indoor Air Quality
Measures
  • CO2 direct with an infra-red sensor 0-20%
  • CO2 ppm 0-10,000ppm
  • CO 0-2,000ppm
  • Differential temperature
  • High accuracy differential pressure meter +/-80mbar
Calculates
  • O2
  • CO/CO2 ratio
  • Excess air
  • Combustion efficiency
Fuel Types
  • Natural Gas
  • Butane
  • Propane
  • LPG
  • 28 sec oil
  • 35 sec oil
  • Wood pellets
Specifications
Parameter Range Resolution Accuracy
Flue Temperature 0-600°C 0.1°C ±2.0°C
±0.3% reading
Inlet Temperature
(Internal Sensor)
0-50°C 0.1°C ±1.0°C
±0.3% reading
Inlet Temperature
(External Sensor)
0-600°C 0.1°C ±2.0°C
±0.3% reading
Oxygen*2 0-21% 0.1% ±0.3%*1
Carbon monoxide 0-20ppm
21-2000ppm nom
4,000ppm max for 15 mins
1ppm ±0.3%*1
±3ppm
±5% reading
Carbon dioxide 0-20% 0.1% ±0.3% reading
Efficiency (Net or Gross)*2 0-99.9% 0.1% ±1.0% reading
Effeciency High (C)*2 0-119.9% 0.1% ±1.0% reading
Excess Air*2 0-250% 0.1% ±0.2% reading
CO/CO2 ratio *2 0-0.999 0.0001 ±5% reading
Nominal range ±160mBar
Maximum over range without damage to sensor is ±800mBar
±0.2mBar
±1 mBar
±160mBar
Maximum
0.001 mBar
<25 mBar
±0.005 mBar
±0.03 mBar
±3% of reading
Pre-programmed Fuels Natural gas, Propane, Butanem LPG, Light Oils (28/35 sec), Wood Pellets
Ambient Measurements
Carbon Monoxide
As above
Carbon Dioxide 0 to 5000ppm 1ppm ±5% reading
5001 to 9999ppm 5ppm ±8%reading
Storage Capacity 99 Combustion tests
20 Pressure tests
20 Tightness tests
20 Temperature tests
20 Room CO tests
20 Ambient tests
up to 240 times tests (one sequence only)
Ambient Operating Range Temperature – 0°C to 40°C
Humidity – 10% to 90% RH non-condensing
Atmospheric Pressure – 860 to 1060hPa
Battery Type / Life 4AA cells
>8 hours using Alkaline AA cells
Chargers (optional) 220v charger, for NiMH batteries only
12v in vehicle charger, for NiMH batteries only
Dimensions Weight – 0.8kg handset with protective cover
Handset – 200 x 45 x 90mm
Probe – 300mm long including handle. 6mm diameter x 240mm long stainless steel shaft with 3m neoprene hose. Type K thermocouple
*1 Using dry gases at STP
*2 Calculated
Optional wireless upgrade
  • Transfer analyser readings to your PC using a KANE LIVE software.
  • Send printout data to your mobile device using the free Kane printer app.
option.name

BTM/450
Wireless android module

 

option.name

BTM/450LE
Wireless iOS module

 

Kane 457 Flue Gas & Ambient Air Analyser Kit - Kane 457 Kit
Unique - ambient & flue CO2 in one analyser Ideal for commercial catering & incident investigations
Kane 457 Flue Gas & Ambient Air Analyser Kit measures carbon dioxide (CO2), carbon monoxide (CO), differential temperature and differential pressure. The direct measurement of CO2 is achieved using a Kane designed infra-red sensing system. CO2 is measured at both flue gas concentrations and at ambient concentrations using two separate sensing systems. These sensing systems are automatically compensated for changes in ambient temperature and in atmospheric pressure. Low flow is automatically detected in both combustion and ambient modes. It can be triggered by low battery voltage, a kinked hose, a full water trap, saturated particle filter or a blockage in the hose or probe. Flue CO2 in % is set to zero in fresh air automatically after the initial countdown. For extra accuracy ambient CO2 in ppm is set to a true zero using a Kane 'ZeroCal Capsule'. If “RESET GAS ZERO” is indicated ensure that the unit is in fresh air before pressing the button with an “Enter” symbol. It calculates oxygen (O2), CO/CO2 ratio, losses, combustion efficiency (Nett, Gross or Condensing) & excess air. The Kane 457 Combustion Analyser Kit can also measure CO levels in ambient air - useful when a CO Alarm is triggered. It can also perform a Room CO + CO2 Test for up to 30 minutes duration. The Kane Flue Gas analyser has a rubber protective cover with a magnet for “hands–free” operation and is supplied with a flue probe with integral temperature sensor. The large display shows 4 readings at a time and all data can be printed via an optional infrared printer. The printed data can be 'live' data or ‘stored’ data. The memory can store up to:
  • 99 combustion tests
  • 20 pressure tests
  • 20 let-by/tightness tests
  • 20 temperature tests
  • 20 room tests
  • 20 ambient tests
  • 240 timed tests
Two lines of 20 characters can be added to the header of printouts. The Kane 457 Flue Gas analyser is controlled using 4 function buttons and a rotary dial. The four buttons (from left to right) switch on and off the analyser, switch on and off the back light and task light, switch on and off the pump and send data to a printer or to the memory. The buttons with UP, DOWN and ENTER arrows also change settings such as date, time, fuel, etc. when in MENU mode. The Kane 457 Combustion Analyser Kit is now available for Heatingspares247.com, Kane Approved Stockist at a special Price.